Commercial Metering - 240V
Commercial Metering - 480V
Current Transformer Section with Disconnect
Current Transformer Cabinet
Accessories
THE CATALOG NUMBERS OF THE EQUIPMENT SHOWN IN THIS WEBSITE ARE NON UTILITY SPECIFIC. ANY EQUIPMENT INSTALLED IN A UTILITY SERVICE AREA MUST BE APPROVED BY THAT UTILITY AND CONFIGURED TO ITS REQUIREMENTS.

PLEASE CONTACT YOUR LOCAL REPRESENTATIVE OR OUR FACTORY REGARDING SPECIFIC UTILITY APPLICATIONS AND CATALOG NUMBERS. NOT ALL CATALOG NUMBERS ARE DISPLAYED IN THIS WEBSITE. IF YOU DO NOT SEE A CATALOG NUMBER YOU ARE LOOKING FOR, PLEASE CALL THE FACTORY DIRECT.
All Categories > Commercial Metering - 480V > Combination Current Transformer Section and Disconnect 400A- 800A Top Exit > Item # CTB-LD-466N-6CM8  
Request Information

Item # CTB-LD-466N-6CM8




    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  


  • This equipment is compatible with type 6 cm metering equipment and must be used in conjunction with a main switch, main circuit breaker or terminal box.
  • This equipment must be used in conjunction with a transformer rated meter fitting per the utility company requirements.


400, 600 and 800 Amp. Combination Current Transformer Section and Disconnect (Disconnect at Top)

larger image

Dimensional Drawing

larger image



Specifications · Features · Application · Notes

Specifications

Type

Current Transformer Section with Circuit Breaker Disconnect (480 Y/277 V)

Current Rating

600 A

Breaker Type

LD

Load Lug Size

2-500 kcmil

Short Circuit Withstand Rating

35,000 RMS Sym. Amps.

Enclosure

Type 3R Aluminum

Phase

Three

Wire

4

Voltage

277 V
480 V

Connection Type

Wye

Ratings

Current transformer section and disconnect are rated 400, 600 or 800 Amp, 3 phase 4 W, 480 Y/277 V Systems. Main Bus is rated 1200 Amp

Use

Indoor
Outdoor

Approvals

Approvals
UL Listed



Features
  • Type 3R enclosures for outdoor or indoor installations.
  • Gangable and compatible with type CM metering equipment.
  • Simple to install with single-bolt main bus bar joints.
  • Aluminum enclosures install easily, never rust.
  • Disconnects available are 400 Amp thru 800 Amp circuit breakers.
  • Listed by underwriters laboratories INC., file E12208.
  • Disconnect at top allows load cables to exit at top or through back.




Application
    For use with Erickson type '6CM' commercial metering panel boards and other metering equipment where a 400, 600 or 800 AMP. current transformer section and disconnect are needed.




Notes
    End covers are removable, & are to be installed on end units using carriage bolts to prevent unauthorized access to bus bars.
    Enclosures are type 3R, for outdoor or indoor use.
    Application: 480Y/277VAC. 3 Phase, 4W