Erickson Electrical Equipment Co. - Item # CTA-T-425N-CM8, Current Transformer Section w/Class 'T' Fusible Disconnect Switch (240 V)
Erickson Electrical Equipment commercial metering equipment
Call Toll Free: 800-952-7225 - sales@ericksonelectric.com
home
about us
products
quote/info request
representation/contact us
Commercial Metering - 240V
Commercial Metering - 480V
Current Transformer Section with Disconnect
Current Transformer Cabinet
Accessories
THE CATALOG NUMBERS OF THE EQUIPMENT SHOWN IN THIS WEBSITE ARE NON UTILITY SPECIFIC. ANY EQUIPMENT INSTALLED IN A UTILITY SERVICE AREA MUST BE APPROVED BY THAT UTILITY AND CONFIGURED TO ITS REQUIREMENTS.

PLEASE CONTACT YOUR LOCAL REPRESENTATIVE OR OUR FACTORY REGARDING SPECIFIC UTILITY APPLICATIONS AND CATALOG NUMBERS. NOT ALL CATALOG NUMBERS ARE DISPLAYED IN THIS WEBSITE. IF YOU DO NOT SEE A CATALOG NUMBER YOU ARE LOOKING FOR, PLEASE CALL THE FACTORY DIRECT.
All Categories > Accessories > Ground Detectors > Ground Detector - Model WPXVAP > Termination Boxes > Main Switch 400A - 800A Bottom Feed > Single Meter Socket and Disconnect 30A - 200A Top Feed (SMP & SPM) > Combination Current Transformer Section and Disconnect 400A - 800A Bottom Exit > Item # CTA-T-425N-CM8  
Request Information

Item # CTA-T-425N-CM8 Current Transformer Section w/Class 'T' Fusible Disconnect Switch (240 V)




    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  


Current Transformer Section w/Class 'T' Fusible Disconnect Switch (240 V)
  • This equipment is compatible with type CM metering equipment and must be used in conjunction with a main switch, main circuit breaker or terminal box.
  • This equipment must be used in conjunction with a transformer rated meter fitting per the utility company requirements. Maximum height of meter fitting as per utility co. requirements. specify utility company service area.


400, 600 and 800 Amp. Combination Current Transformer Section and Disconnect

larger image

Dimensional Drawing

larger image




Specifications

Current Rating

400 A

Switch Type

 Question? 
Bolted Pressure

Load Lug Size

1-600 kcmil

Short Circuit Withstand Rating

200,000 RMS Sym. Amps.

Phase

Three

Wire

4

Max. Voltage

240 V

Enclosure

Type 3R Aluminum

Ratings

Current transformer section and disconnect are rated 400, 600 or 800 Amp, 240 Volts max. main bus is rated 1200 Amp

Use

Indoor/Outdoor

Approvals

Approvals
UL Listed